The pain: four panels and one plug
The shopping page says 800 W or 1,200 W. The carton has two panels, or four. The microinverter is a small box with one cord. People add the panel stickers, get 1,600 W, and think they bought a 1,600 W legal system. The statute, where we have one, is counting what the inverter sends into the outlet.
AC cap versus panel stickers
Our state-law tracker uses these ceilings: 1,200 W in Utah, Maryland, Vermont, Connecticut, California, New Hampshire, Virginia, New Jersey, and the pending New York bill; 1,920 W in Colorado; and, in Maine's summaries, 420 W if you install it yourself, up to 1,200 W with a licensed electrician. Those numbers are device output. The Clean Energy States Alliance brief describes the same split: panels are DC, the cap is AC, and an inverter fed with extra DC watts clips rather than becoming a larger legal system.
Clipping means a bright hour is flattened at the inverter's AC rating. Two 500 W panels on an 800 W inverter can add up to 1,000 W of DC nameplate and still only deliver 800 W AC when both are in full sun. You did not cheat the cap. You also did not get 1,000 W into the house.
How many panels per microinverter
Read two lines on the inverter label. The first is maximum continuous AC output. The second is how many DC inputs it has, and the module watts, voltage, and current each input allows.
- One input: one panel, and that panel has to sit inside the voltage window. The AC rating might be 300 to 500 W. Several of those on one circuit add up. Stop at the state cap and at the breaker.
- Two inputs: two panels. This is the usual balcony shape. Each input tracks its own panel. The AC output is still one number for the whole box.
- More panels than inputs: not by splicing two modules onto one input unless the manufacturer lists that pair. Parallel strings are a design, not a balcony shortcut.
A published example is the APsystems EZ1-LV. The maker's consumer page says it connects one or two panels, with AC output up to 900 W, and a recommended module range of about 315 W to 660 W per input. This site does not sell that inverter. The example is here so the ratio is concrete: two panels, 900 W AC, which sits under a 1,200 W statutory cap and does not equal 660 + 660 of legal output.
800 W of AC output wants an inverter rated at 800 W, or an inverter rated higher that you are not allowed to run higher because of the cap. 1,200 W of AC output wants an inverter whose continuous rating is 1,200 W or less if 1,200 W is the legal ceiling. An inverter rated 1,500 W does not become legal because you "only bought 1,200 W of panels." If it can send 1,500 W, the cap conversation is about the inverter.
800 W versus 1,200 W in the house
At 120 volts, 800 W is about 6.7 amps and 1,200 W is 10 amps. A 15-amp breaker used continuously is often held to 12 amps, about 1,440 W. Both sizes fit that arithmetic. They do not fit the same daytime load. If the home only draws 400 W at noon, an 1,200 W inverter exports the rest. The laws we track do not pay for that export. The extra energy problem is on the export page.
On the Los Angeles vertical south-facing check, 800 W is about 794 kWh a year. The 1,200 W button on the calculator scales the same weather. Shade, an east railing, and a vertical mount move the result more than the argument between 800 and 1,200. Maine's 420 W self-install line, where the summaries describe it, is a third size. Do not buy the 1,200 W inverter and call 420 W of it a self-install.
What to do, in order
- Look up the cap for your state on the state map. If there is no exemption, a backfeeding inverter is still an interconnection question. California's 1,200 W cap starts January 1, 2027, not today.
- Pick the inverter AC rating first. It has to be at or under the cap, and at or under what the circuit can take. See breaker masking before you pick the outlet.
- Count inputs. Buy that many panels, inside the module range printed for each input. Two inputs, two panels. One input, one panel.
- Do not add a second plug-in inverter to "fill" the cap on the same circuit. The currents add. The breaker may not see the sum.
- If you want more panel area than the cap allows into the wall, the rest of the panels belong on a station or a charge controller, not on a second backfeed. That is a different product, with its own label.
Last checked November 25, 2026. Hardware listings change. Read the label on the unit you buy.
Questions people ask next
Is 800W or 1,200W the panel rating?
In the state laws we track, the cap is the power the device sends into the building. That is AC output from the inverter. Panel ratings are DC nameplate watts. An inverter can be connected to more DC watts than its AC rating. It simply will not send out more than its AC rating on a bright hour.
How many panels can one microinverter take?
As many as it has inputs, and only modules inside the voltage and current window on its label. A dual-input balcony inverter takes two panels. A single-input microinverter takes one. You do not land four panels on two inputs by paralleling them yourself unless the label says that exact combination is allowed.
Can I put two 800W inverters on one outlet to reach 1,200W?
No. Two inverters add their AC current on the same circuit. 800 plus 800 is already past a 1,200 W cap and past the continuous load of a typical 15-amp breaker. One plug-in device per circuit.
What is a real example of two panels on one inverter?
APsystems publishes the EZ1-LV as a balcony microinverter with two inputs and 900 VA maximum continuous AC output. The recommended module range on the maker's page is about 315 W to 660 W per input. That is one manufacturer's spec, not a kit this site sells, and the AC output is 900 W, not 1,200 W. Use it as the shape of the math: two panels, one AC cap.
Does Colorado's 1,920 W cap change the panel count?
It changes the legal AC ceiling in our tracker, not the inverter's input count. You still cannot exceed what that inverter is listed to do. 1,920 W is about 16 amps at 120 volts, which is a different circuit conversation than 10 amps. Read the Colorado page and the breaker-panel page before you size to the higher cap.
Sources
- Our state-law tracker, last checked November 25, 2026: watt caps by state, including 1,200 W, Colorado 1,920 W, and Maine's reported 420 W self-install line.
- APsystems USA, EZ1 consumer page (two panels, up to 900 W AC).
- Clean Energy States Alliance, Plug-In Solar, updated June 2026.
- What size plug-in system, for the daytime-load side of the same choice.